The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.
- Release of new firmware version 2.21 - July 25,2014
- DETAILS
-
- FEATURES
Selecting a data acquisition platform for electronics or mechatronics applications has always been a balancing act. High speed digitizers lack the isolation, attenuation, or bit resolution necessary for power electronics testing. PC-based platforms with fast streaming throughput sacrifice noise immunity, signal conditioning, and hardware integrity.
Until now. The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.
Speed of managing and acquiring data is the highlight of the SL1000.
- Fast Acquisition
- Up to 100 MS/s on all channels (10 ns sampling interval)
- New 100 MS/s 12-Bit 1 kV¹ isolation module with 20 MHz bandwidth
- Supports parallel testing: Perform measurements with up to four simultaneously independent sample rates
- Fast Transfer and Storage
- Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ethernet²
- Real time display on a PC (GIGAZoom engine)³
- Stream data to a PC hard disk or the SL1000's internal hard disk² in real time (at speeds of 1.6 MS/s = 100 kS/s x 16ch)³
- Easy to use
- Easy to use Standard Acquisition Software
- Quick and Intuitive operation means that you can start measuring immediately
- Setup Wizard guides you through detailed settings
- Can operate "Standalone"
- Store data directly on the SL1000
- Wide Library of Plug-In Modules
- Eight module slots are available in each unit
- Select from twelve different plug-in modules
¹: In combination with 10:1 probe (for isolated BNC input) model 700929
²: Optional
³: Speed depends on PC performance and measuring conditions. - Fast Acquisition
- HARDWARE
High-Speed Capture
In the pursuit of isolated high-speed waveform measurements, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s, 12-Bit resolution, 20 MHz frequency range and 1-kV * Isolation Module (model 720210).
Furthermore, you can combine modules that support measurements of a variety of signals, giving you solutions for an extensive range of applications.*: In combination with 10:1 probe (for isolated BNC input ) model 700929
Saving Data over Long Periods of Time
Data can be saved to the SL1000’s internal acquisition memory over long durations, or it can also be streamed in real-time to a PC's hard disk or the SL1000’s internal hard disk ¹ ².
¹: with the /HD1 Option
²: Maximum speed of real time hard disk recording depends on measuring conditions.
³: Trigger mode: Single, measuring on 1 module, 2 channels.Supports parallel testing
Perform measurements with up to four simultaneously independent sample rates. The amount of data saved on hard disk can be reduced by optimizing the sample rate for the DUT on a module by module basis.
High-Speed Data Transfer & GIGAZoom Function
You can transfer data to the PC at high speeds via USB 2.0 or Ethernet 1000BASE-T Gigabit Ethernet¹. The SL1000’s high-speed data compression engine (GIGAZoom engine) displays waveforms on the PC in real time² (even with massive amounts of data at high sample rates). It offers the same display updating and zooming performance as standalone measuring instruments.
¹: with the /C10 Option
²: The number of channels from which waveforms can be displayed during measurement may be limited depending on the PC performance and measuring conditions.Real Time Saving to Hard Disk
Continuously measured data can be saved in real time to a PC's hard disk and/or the SL1000's internal hard disk ¹. File names are assigned automatically, freeing you from time consuming file operations. Data can be saved simultaneously - and in real time - to both the PC’s and SL1000's hard disks ¹. This bolsters the reliability of your data storage system, protecting your vital data. You can access the SL1000's internal hard disk ¹ with Xviewer waveform viewer software, or through an FTP client over Ethernet ².
¹: with the /HD1 Option
²: with the /C10 Option
³: Typical values. Actual values depend on PC performance and measurement conditions.Settings for the Hard Disk Recording Function
By using the various recording features, you can efficiently and automatically record only the data you need to the hard disk. Just specify the recording destination, recording start and stop conditions, conditions for repeating recording, and other criteria. With free run mode, the specifiable parameters for the recording start condition are immediate, time, and alarm; for the recording stop condition, the parameters are continuous, time, recording time, and alarm; and for the repeating condition, recording interval and number of recordings*. With triggered mode, measured data is recorded on each trigger. You can also manually save data from the SL1000's internal acquisition memory to PC hard disk.
*: Max. file size per recording is 12 GB (recording on 4 channels, approximately 1.5 GW/ch)
Multi Units Synchronization
Maximum 8 Synchronized Units
- 100 MS/s up to 128 ch (16ch x 8 units)
- Can use 4 different sample rates across all units (Supports Parallel testing)
- Can combine trigger and alarm for channels across all units
- Maximum speed for saving in real time1 PC HDD: 1.6 MS/s = 100kS/s x 16ch > 10kS/s x 128ch (Total data transfer rate to PC HDD is 1.6MS/s) Unit HDD: 1.6MS/s = 100kS/s x 16ch (100kS/s x 128ch with 8 units)
(Note)
In synchronized unit mode, recording into PC and SL1000 embedded HDD at the same time is not possible.
The recording file is per unit basis. (Utility software interface.) - SOFTWARE
Setting Marks (NEW)
You can input the comments in the mark area when monitoring (Free run mode) over long periods of time.Setting Marks
You can input the comments in the mark area when monitoring (Free run mode) for a long time.Real time X-Y Display (NEW)
You can now see both the T-Y and X-Y waveform Display. It is easy to evaluate data with fast update.
Auto Play (NEW)
It is easy to set zoom position of waveform when measuring over long periods of time data or large data.File Utility Function (NEW)
You can save the data in both ASCII and Binary format. You can also load data with the same analysis program (ex. MatLAB).Setting Operation Display
Accumulating Waveforms (NEW)
You can easily detect unevenness or changes in acquired data.
Sample of Accumulate Display
Setup Wizard Makes It Easy
The Wizard automatically recognizes any connected SL1000 and its' plug-in modules. Just click the Start button to start measuring right away - no complicated settings to enter. The four screens of the Setup Wizard guide you easily through detailed settings for configuring the system, measuring, saving and displaying. Of course, you can save and recall your settings at any time.
Individual Sample Rates for Each Measurement Channel Group
Up to four groups of measurement channels can be defined with individual measurement conditions and display settings. Even waveforms from groups with different sample rates can be displayed in the same window.
Easy Tabular Setup Screens
Measurement conditions and channel display settings can be viewed and set easily using a tabular format. Use drag and drop shortcuts to quickly setup multiple channels.
Measurement condition setting screen Display setting screen
Control Buttons - Just Like Your DVD Remote
Measurement and saving can be started and stopped using the same familiar buttons found on a DVD remote control. Start using the instrument on the same day you receive it, with absolutely no programming required.
Real Time Waveform Display and Analysis
You can display a zoomed portion of the waveform simultaneously with the overall waveform during triggered measurement. Even during live recording, you can use the display hold * to review past data. You can also perform cursor measurements or automated measurement of waveform parameters (up to 26 during triggered measurement) in real time.
*: The display hold may automatically switch to display resume depending on the measuring conditions.
Easy Display Setup
Adjust your vertical display scale with ease using mouse shortcuts.
File Transfer
Adjust your vertical display scale with ease using mouse shortcuts.The File Transfer Function transfers files from the SL1000 to PC via, the Acquisition Software, intelligently in the case of multiple synchronized units.
File Utility *
SL1000 File Utility is file processing software for manipulating acquired files before analyzing waveforms with Xviewer. It can also analyze multiple channels across several units at the same time. * SL1000 File Utility is bundled with the SL1000 standard install CD.
File interface operation screen (example)
- FEATURES
- ACCESSORIES
BNC cable 366926
A 1 m long BNC-alligator clip cable.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for DL750/DL750P, SL1000 & SL1400Measurement Lead 366961
A subassembly of 1.2 m long test leads with alligator-clip adapters.
Use only for circuits having voltage levels no greater than 42 V.
Applicable for SL1000 & SL1400.Analog Voltage Input Module 701250
High-Speed 10 Ms/s 12-Bit Isolation Module (2 ch)
High Noise Immunity
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000Analog Voltage Input Module 701251
High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
High sensitivity range (10 mV), low noise (±100 µVtyp), and high noise immunity
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000Analog Voltage Input Module 701255
High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
Non-Isolation version of model 701250
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000Universal Voltage & Temperature Input Module 701261
Universal Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000Universal Voltage & Temperature Input Module (w/AAF) 701262
Universal Module (with Anti-Aliasing Filter, 2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000High-Precision Temperature Input Module 701265
Temperature/high-precision voltage Module (2 ch)
Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000Analog Voltage Input Module 701267
High-Voltage 100 kS/s, 16-Bit Isolation Module (2 channels)
Supports RMS input couplingStrain Input Module (NDIS) - 701270
Strain Module, type NDIS (2 channels) to be used in combination with 701955 or 701956 NDIS bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.Strain Input Module (DSUB) 701271
Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.Acceleration & Voltage Input Module (w/AAF) 701275
Acceleraton/Voltage Module with Anti-Aliasing Filter, (2 channels)
Accepts direct input from a built-in amp type acceleration sensor to measure acceleration. Sensor supply current (voltage) OFF/4 mA ± 10% (approx. 22 VDC) Applicable acceleration sensor type: Built-in amplifier type, Kistler Instruments Corp. : PiezotronTM, PCB, Piezotronics Inc. : ICPTM, Endevco Corp : IsotronTM.Frequency Module 701281
Frequency Module (2 ch)
Measurement function Frequency (Hz), RPMs, RPSs, period (sec),duty cycle (%), power supply frequency (Hz), pulse width (sec), pulse integration, and velocity1:1 BNC safety adapter lead 701901
1000 Vrms-CAT II, 1.8 m long
Safety BNC(male) to safety banana(female) use in combination with 701959, 701954, 758921, 758922 or 758929.Safety BNC cable 701902/701903
701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
701903: 1000 Vrms-CAT II (BNC-BNC), 2 mCurrent Probe 10 MHz/150 ARMS 701930
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Current Probe 2 MHz/500 ARMS 701931
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Current Probe 50 MHz/30 ARMS 701933
Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.
Probe Power Supply 701934
A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.
10 MHz Passive Probe 701940
Passive Probe, 600Vp, 6MHz/10MHz, 1:1, 10:1, 1MΩ/10MΩ, 1.5m '600V Non-Isolated'
Alligator Clip (dolphin type) 701954
Set contains one black and one red clip.
1000 Vrms-CAT II.NDIS bridge heads 701955/701956
701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable includedD-sub Bridge Heads 701957/701958
701957 DSUB Bridge Head with Shunt calibration
Bridge resistance: 120Ω , 5m DSUB cable included701958 DSUB Bridge Head with Shunt calibration
Bridge resistance: 350Ω , 5m DSUB cable includedSafety mini clip (hook type) 701959
Set contains one black and one red clip. 1000 Vrms-CAT II.
Analog Voltage Input Module 720210
High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)
IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.Fork terminal adapter 758921
Adapters for fitting a 4mm banana plug to a fork terminal. Set contains one black and one red clip. 1000 Vrms-CAT II.
Small Alligator-clip Adapter 758922
Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
Applicable for DL750/DL750P, SL1000, SL1400Conversion Adapter 758924
For conversion between BNC and female banana plug
Applicable for DL750/DL750P, SL1000 & SL1400.Large Alligator-clip Adapter 758929
Rated at 1000V. Attaches to the 758917 test leads. Sold in pairs.
Applicable for DL750/DL750P, SL1000, SL1400.