YOKOGAWA MALAYSIA DISTRIBUTOR,YOKOGAWA MALAYSIA SUPPLIER,YOKOGAWA MALAYSIA STOCKIST,YOKOGAWA MALAYSIA TRAINER

YOKOGAWA HIGH-SPEED DATA ACQUISITION UNIT SL1000

Category: SCOPECORDERS

The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.


- Release of new firmware version 2.21 - July 25,2014

  • DETAILS
    • FEATURES

      Selecting a data acquisition platform for electronics or mechatronics applications has always been a balancing act. High speed digitizers lack the isolation, attenuation, or bit resolution necessary for power electronics testing. PC-based platforms with fast streaming throughput sacrifice noise immunity, signal conditioning, and hardware integrity.

      Until now. The new Yokogawa SL1000 is the only data acquisition system that delivers independent, isolated channel hardware at 100MS/ch rates, with no compromise in bit resolution, memory depth, or streaming performance.

      Speed of managing and acquiring data is the highlight of the SL1000.

      • Fast Acquisition
        • Up to 100 MS/s on all channels (10 ns sampling interval)
        • New 100 MS/s 12-Bit 1 kV¹ isolation module with 20 MHz bandwidth
        • Supports parallel testing: Perform measurements with up to four simultaneously independent sample rates
      • Fast Transfer and Storage
        • Stream data to PC via high speed USB 2.0 or 1000BASE-T Gigabit Ethernet²
        • Real time display on a PC (GIGAZoom engine)³
        • Stream data to a PC hard disk or the SL1000's internal hard disk² in real time (at speeds of 1.6 MS/s = 100 kS/s x 16ch)³ 
      • Easy to use
        • Easy to use Standard Acquisition Software
        • Quick and Intuitive operation means that you can start measuring immediately
        • Setup Wizard guides you through detailed settings
      • Can operate "Standalone"
        • Store data directly on the SL1000
      • Wide Library of Plug-In Modules
        • Eight module slots are available in each unit
        • Select from twelve different plug-in modules

      ¹: In combination with 10:1 probe (for isolated BNC input) model 700929
      ²: Optional
      ³: Speed depends on PC performance and measuring conditions.

    • HARDWARE

      High-Speed Capture

      In the pursuit of isolated high-speed waveform measurements, Yokogawa has achieved a maximum sample rate of 100 MS/s (10 ns sampling interval). The SL1000 can accurately capture high-speed and high-voltage phenomena by using the newly developed 100 MS/s, 12-Bit resolution,  20 MHz frequency range and 1-kV * Isolation Module (model 720210).
      Furthermore, you can combine modules that support measurements of a variety of signals, giving you solutions for an extensive range of applications.

      *: In combination with 10:1 probe (for isolated BNC input ) model 700929


       High Speed Capture


      Saving Data over Long Periods of Time

      Data can be saved to the SL1000’s internal acquisition memory over long durations, or it can also be streamed in real-time to a PC's hard disk or the SL1000’s internal hard disk ¹ ².

      Sample Rate V Recording Time


      ¹:  with the /HD1 Option
      ²:  Maximum speed of real time hard disk recording depends on measuring conditions.
      ³:  Trigger mode: Single, measuring on 1 module, 2 channels.  

      Supports parallel testing 

      Perform measurements with up to four simultaneously independent sample rates. The amount of data saved on hard disk can be reduced by optimizing the sample rate for the DUT on a module by module basis.

      Support Parallel Testing

      High-Speed Data Transfer & GIGAZoom Function 

      You can transfer data to the PC at high speeds via USB 2.0 or Ethernet 1000BASE-T Gigabit Ethernet¹. The SL1000’s high-speed data compression engine (GIGAZoom engine) displays waveforms on the PC in real time² (even with massive amounts of data at high sample rates).  It offers the same display updating and zooming performance as standalone measuring instruments.

      ¹:  with the /C10 Option
      ²:  The number of channels from which waveforms can be displayed during measurement may be limited depending on the PC performance and measuring conditions.

      Giga Color Black R


      Giga Zoom Function

      Real Time Saving to Hard Disk 

      Continuously measured data can be saved in real time to a PC's hard disk and/or the SL1000's internal hard disk ¹. File names are assigned automatically, freeing you from time consuming file operations. Data can be saved simultaneously - and in real time - to both the PC’s and SL1000's hard disks ¹. This bolsters the reliability of your data storage system, protecting your vital data. You can access the SL1000's internal hard disk ¹ with Xviewer waveform viewer software, or through an FTP client over Ethernet ².

      Real Time Saving To Hard Disk 2

      Real Time Saving To Hard Disk 

      ¹: with the /HD1 Option
      ²: with the /C10 Option
      ³: Typical values. Actual values depend on PC performance and measurement conditions.

      Settings for the Hard Disk Recording Function 

      By using the various recording features, you can efficiently and automatically record only the data you need to the hard disk. Just specify the recording destination, recording start and stop conditions, conditions for repeating recording, and other criteria. With free run mode, the specifiable parameters for the recording start condition are immediate, time, and alarm; for the recording stop condition, the parameters are continuous, time, recording time, and alarm; and for the repeating condition, recording interval and number of recordings*. With triggered mode, measured data is recorded on each trigger. You can also manually save data from the SL1000's internal acquisition memory to PC hard disk.

      *: Max. file size per recording is 12 GB (recording on 4 channels, approximately 1.5 GW/ch)

      Setting Hard Disk Recording Function

      Multi Units Synchronization

      Maximum 8 Synchronized Units

      • 100 MS/s up to 128 ch (16ch x 8 units)
      • Can use 4 different sample rates across all units
      • (Supports Parallel testing)
      • Can combine trigger and alarm for channels across all units
      • Maximum speed for saving in real time1
      • PC HDD: 1.6 MS/s = 100kS/s x 16ch > 10kS/s x 128ch (Total data transfer rate to PC HDD is 1.6MS/s) Unit HDD: 1.6MS/s = 100kS/s x 16ch (100kS/s x 128ch with 8 units)
      1: Typical values. Actual values depend on PC performance and measurement conditions
      Tm Sl1000 20
       
      (Note)
      In synchronized unit mode, recording into PC and SL1000 embedded HDD at the same time is not possible.
      The recording file is per unit basis. (Utility software interface.)


    • SOFTWARE

      Setting Marks (NEW)


      You can input the comments in the mark area when monitoring (Free run mode) over long periods of time.
      SL1000 Software 1 Setting Marks
      You can input the comments in the mark area when monitoring (Free run mode) for a long time.

       

      Real time X-Y Display (NEW)

      You can now see both the T-Y and X-Y waveform Display. It is easy to evaluate data with fast update.
      SL1000 Software 2 2

      Auto Play (NEW)

      It is easy to set zoom position of waveform when measuring over long periods of time data or large data.

      SL1000 Software 3 1

       

      SL1000 Software 4

      File Utility Function (NEW)

      You can save the data in both ASCII and Binary format. You can also load data with the same analysis program (ex. MatLAB).

      SL1000 Software 5

      Setting Operation Display

      Accumulating Waveforms (NEW)

      You can easily detect unevenness or changes in acquired data.

      SL1000 Software 6


      Sample of Accumulate Display

      Setup Wizard Makes It Easy 

      The Wizard automatically recognizes any connected SL1000 and its' plug-in modules. Just click the Start button to start measuring right away - no complicated settings to enter. The four screens of the Setup Wizard guide you easily through detailed settings for configuring the system, measuring, saving and displaying. Of course, you can save and recall your settings at any time.

      Setup Wizard

      Individual Sample Rates for Each Measurement Channel Group 

      Up to four groups of measurement channels can be defined with individual measurement conditions and display settings. Even waveforms from groups with different sample rates can be displayed in the same window.

      Individual Sample Rate

      Easy Tabular Setup Screens 

      Measurement conditions and channel display settings can be viewed and set easily using a tabular format. Use drag and drop shortcuts to quickly setup multiple channels.

      Easy Tabular Setup

      Measurement condition setting screen Display setting screen

      Control Buttons - Just Like Your DVD Remote 

      Measurement and saving can be started and stopped using the same familiar buttons found on a DVD remote control. Start using the instrument on the same day you receive it, with absolutely no programming required. 

      Control Button 

      Real Time Waveform Display and Analysis 

      You can display a zoomed portion of the waveform simultaneously with the overall waveform during triggered measurement. Even during live recording, you can use the display hold * to review past data. You can also perform cursor measurements or automated measurement of waveform parameters (up to 26 during triggered measurement) in real time.

      *:  The display hold may automatically switch to display resume depending on the measuring conditions.  

      Easy Display Setup

      Adjust your vertical display scale with ease using mouse shortcuts.

      Tm Sl1000 21

      File Transfer

      Adjust your vertical display scale with ease using mouse shortcuts.The File Transfer Function transfers files from the SL1000 to PC via, the Acquisition Software, intelligently in the case of multiple synchronized units.

      Tm Sl1000 22

      File Utility *

      SL1000 File Utility is file processing software for manipulating acquired files before analyzing waveforms with Xviewer. It can also analyze multiple channels across several units at the same time.

      * SL1000 File Utility is bundled with the SL1000 standard install CD.

       Tm Sl1000 23
      File interface operation screen (example)
        Tm Sl1000 24
  • ACCESSORIES
     

    BNC cable 366926

    BNC cable 366926

    A 1 m long BNC-alligator clip cable.
    Use only for circuits having voltage levels no greater than 42 V.
    Applicable for DL750/DL750P, SL1000 & SL1400

    Measurement Lead 366961

    Measurement Lead 366961

    A subassembly of 1.2 m long test leads with alligator-clip adapters.
    Use only for circuits having voltage levels no greater than 42 V.
    Applicable for SL1000 & SL1400.

    Analog Voltage Input Module 701250

    Analog Voltage Input Module 701250

    High-Speed 10 Ms/s 12-Bit Isolation Module (2 ch)
    High Noise Immunity
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    Analog Voltage Input Module 701251

    Analog Voltage Input Module 701251

    High-Speed 1 Ms/s 16-Bit Isolation Module (2 ch)
    High sensitivity range (10 mV), low noise (±100 µVtyp), and high noise immunity
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    Analog Voltage Input Module 701255

    Analog Voltage Input Module 701255

    High-Speed 10 MS/s 12-Bit non-isolation Module (2 ch)
    Non-Isolation version of model 701250
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    Universal Voltage & Temperature Input Module 701261

    Universal Voltage & Temperature Input Module 701261

    Universal Module (2 ch)
    Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel)
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    Universal Voltage & Temperature Input Module (w/AAF) 701262

    Universal Voltage & Temperature Input Module (w/AAF) 701262

    Universal Module (with Anti-Aliasing Filter, 2 ch)
    Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), with AAF
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    High-Precision Temperature Input Module 701265

    High-Precision Temperature Input Module 701265

    Temperature/high-precision voltage Module (2 ch)
    Thermocouple (K, E, J, T, L, U, N, R, S, B, W, iron-doped gold/chromel), high sensitivity range (1 mV), and low noise (±4 µVtyp)
    Applicable to DL850, DL850V, DL750, DL750P, SL1400 & SL1000

    Analog Voltage Input Module 701267

    Analog Voltage Input Module 701267

    High-Voltage 100 kS/s, 16-Bit Isolation Module (2 channels)
    Supports RMS input coupling

    Strain Input Module (NDIS) - 701270

    Strain Input Module (NDIS) - 701270

    Strain Module, type NDIS (2 channels) to be used in combination with 701955 or 701956 NDIS bridge head.
    Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.

    Strain Input Module (DSUB) 701271

    Strain Input Module (DSUB) 701271

    Strain Module with Shunt Calibration, type DSUB (2 channels) to be used in combination with 701957 or 701958 DSUB bridge head.
    Using the strain module and strain gauge the ScopeCorder can detect and display mechanical stress (strain). It works on the principle that the resistance value of a metal foil changes as it expands and contracts.

    Acceleration & Voltage Input Module (w/AAF) 701275

    Acceleration & Voltage Input Module (w/AAF) 701275

    Acceleraton/Voltage Module with Anti-Aliasing Filter, (2 channels)
    Accepts direct input from a built-in amp type acceleration sensor to measure acceleration. Sensor supply current (voltage) OFF/4 mA ± 10% (approx. 22 VDC) Applicable acceleration sensor  type: Built-in amplifier type, Kistler Instruments Corp. : PiezotronTM, PCB, Piezotronics Inc. : ICPTM, Endevco Corp : IsotronTM.

    Frequency Module 701281

    Frequency Module 701281

    Frequency Module (2 ch)
    Measurement function Frequency (Hz), RPMs, RPSs, period (sec),duty cycle (%), power supply frequency (Hz), pulse width (sec), pulse integration, and velocity

    1:1 BNC safety adapter lead 701901

    1:1 BNC safety adapter lead 701901

    1000 Vrms-CAT II, 1.8 m long
    Safety BNC(male) to safety banana(female) use in combination with 701959, 701954, 758921, 758922 or 758929.

    Safety BNC cable 701902/701903

    Safety BNC cable 701902/701903

    701902: 1000 Vtms-CAT II (BNC-BNC), 1 m
    701903: 1000 Vrms-CAT II (BNC-BNC), 2 m

    Current Probe 10 MHz/150 ARMS 701930

    Current Probe 10 MHz/150 ARMS 701930

    Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

    Current Probe 2 MHz/500 ARMS 701931

    Current Probe 2 MHz/500 ARMS 701931

    Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

    Current Probe 50 MHz/30 ARMS 701933

    Current Probe 50 MHz/30 ARMS 701933

    Current probe powered by Yokogawa Digital Oscilloscopes, Scopecorders or external power supply.

    Probe Power Supply 701934

    Probe Power Supply 701934

    A power supply for current probes, FET probes, and differential probes. Supplies power for up to four probes, including large current probes.

    10 MHz Passive Probe 701940

    10 MHz Passive Probe 701940

    Passive Probe, 600Vp, 6MHz/10MHz, 1:1, 10:1, 1MΩ/10MΩ, 1.5m '600V Non-Isolated'

    Alligator Clip (dolphin type) 701954

    Alligator Clip (dolphin type) 701954

    Set contains one black and one red clip.
    1000 Vrms-CAT II.

    NDIS bridge heads 701955/701956

    NDIS bridge heads 701955/701956

    701955 NDIS Bridge Head, Bridge resistance: 120Ω , 5m NDIS cable included
    701956 NDIS Bridge Head, Bridge resistance: 350Ω , 5m NDIS cable included

    D-sub Bridge Heads 701957/701958

    D-sub Bridge Heads 701957/701958

    701957 DSUB Bridge Head with Shunt calibration
    Bridge resistance:  120Ω , 5m DSUB cable included

    701958 DSUB Bridge Head with Shunt calibration
    Bridge resistance:  350Ω , 5m DSUB cable included

    Safety mini clip (hook type) 701959

    Safety mini clip (hook type) 701959

    Set contains one black and one red clip. 1000 Vrms-CAT II.

    Analog Voltage Input Module 720210

    Analog Voltage Input Module 720210

    High-Speed 100 MS/s 12-Bit Isolation Module (2 channels)
    IsoPRO technology enables 1kV isolated measurements in combination with 700929 or 701947 probe and is designed for inverter / IGBT related applications in mind. Using high speed optical fiber-based transmission, the module achieves high speed ADC clock and data isolation and provides the performance needed to develop high  efficiency inverters, which employ high voltages, large currents, and ever increasing switching speeds.

    Fork terminal adapter 758921

    Fork terminal adapter 758921

    Adapters for fitting a 4mm banana plug to a fork terminal. Set contains one black and one red clip. 1000 Vrms-CAT II.

    Small Alligator-clip Adapter 758922

    Small Alligator-clip Adapter 758922

    Rated at 300 V. Attaches to the 758917 test leads. Sold in pairs.
    Applicable for DL750/DL750P, SL1000, SL1400

    Conversion Adapter 758924

    Conversion Adapter 758924

    For conversion between BNC and female banana plug
    Applicable for DL750/DL750P, SL1000 & SL1400.

    Large Alligator-clip Adapter 758929

    Large Alligator-clip Adapter 758929

    Rated at 1000V. Attaches to the 758917 test leads. Sold in pairs.
    Applicable for DL750/DL750P, SL1000, SL1400.

Location

Ask about this product